The rated capacity of this oil immersed power transformer is 315KVA . It can be used outdoors or installed inside substations.
The models that can be selected for oil immersed transformers include S9, S11, S13, S15, and so on.
The high-voltage part of oil immersed transformers can also be selected from 6KV, 6.3KV, 10KV, 10.5KV, 11KV, 20KV, 25KV, 33KV, 35KV, and so on
The low voltage part of oil immersed transformers can also be selected: 400V, 415V, 0.4KV, etc. It can be configured according to the actual situation in your local area.
Rated capacity (kVA) | H.V. (kV) |
Tapping range | L.V. (kV) | Vector group | Loss(kW) | No-load current (%) | Impedance voltage (%) | Weight (kg) | ||
Load loss | No-load loss | oil | Total | |||||||
10 | 6,10,11 | ±5% or ±2*2.5% | 0.4 0.415 0.433 | Dyn11 or Yyn0 |
0.26 | 0.09 | 3.2 | 4 | 45 | 172 |
20 | 0.44 | 0.10 | 3.0 | 65 | 240 | |||||
30 | 0.63 | 0.13 | 2.3 | 65 | 245 | |||||
50 | 0.91 | 0.17 | 2.0 | 80 | 330 | |||||
63 | 1.09 | 0.20 | 1.9 | 90 | 365 | |||||
80 | 1.31 | 0.25 | 1.9 | 95 | 410 | |||||
100 | 1.58 | 0.29 | 1.8 | 115 | 490 | |||||
125 | 1.89 | 0.34 | 1.7 | 140 | 620 | |||||
160 | 2.31 | 0.40 | 1.6 | 155 | 720 | |||||
200 | 2.73 | 0.48 | 1.5 | 175 | 810 | |||||
250 | 3.20 | 0.56 | 1.4 | 200 | 940 | |||||
315 | 3.85 | 0.67 | 1.4 | 215 | 1090 | |||||
400 | 4.52 | 0.80 | 1.3 | 240 | 1250 | |||||
500 | 5.41 | 0.96 | 1.2 | 285 | 1460 | |||||
630 | 6.20 | 1.20 | 1.1 | 4.5 | 345 | 1720 | ||||
800 | 7.50 | 1.40 | 1.1 | 390 | 2050 | |||||
1000 | 10.30 | 1.70 | 1.0 | 460 | 2430 | |||||
1250 | 12.00 | 1.95 | 1.0 | 550 | 2850 | |||||
1600 | 14.50 | 2.40 | 0.8 | 690 | 3600 | |||||
2000 | 18.00 | 2.60 | 0.7 | 790 | 4300 |
Rated capacity(kVA) | H.V. (kV) | Tapping range | L.V. (kV) | Vector group | Loss(kW) | No-load current (%) | Impedance voltage (%) | Weight (kg) | ||
Load loss | No-load loss | oil | Total | |||||||
30 | 15,20 | ±5% or ±2*2.5% | 0.4,0.415. 0.433 | Dyn11 or Yyn0 |
0.60 | 0.10 | 2.1 | 4 | 85 | 350 |
50 | 0.87 | 0.13 | 2.0 | 90 | 480 | |||||
63 | 1.04 | 0.15 | 1.9 | 110 | 600 | |||||
80 | 1.25 | 0.18 | 1.8 | 110 | 660 | |||||
100 | 1.50 | 0.20 | 1.6 | 120 | 700 | |||||
125 | 1.80 | 0.24 | 1.5 | 130 | 800 | |||||
160 | 2.20 | 0.29 | 1.4 | 140 | 940 | |||||
200 | 2.60 | 0.33 | 1.2 | 160 | 1130 | |||||
250 | 3.05 | 0.40 | 1.2 | 180 | 1290 | |||||
315 | 3.65 | 0.48 | 1.1 | 230 | 1400 | |||||
400 | 4.30 | 0.57 | 1.0 | 250 | 1550 | |||||
500 | 5.15 | 0.68 | 1.0 | 260 | 1780 | |||||
630 | 6.20 | 0.81 | 0.9 | 4.5 | 320 | 2100 | ||||
800 | 7.50 | 0.98 | 0.8 | 350 | 2560 | |||||
1000 | 10.30 | 1.15 | 0.7 | 450 | 2800 | |||||
1250 | 12.00 | 1.36 | 0.6 | 490 | 3200 | |||||
1600 | 14.50 | 1.64 | 0.6 | 640 | 4000 | |||||
2000 | 17.14 | 1.94 | 0.6 | 800 | 4900 | |||||
2500 | 20.26 | 2.30 | 0.5 | 1180 | 6300 |
Rated capacity(kVA) | H.V. (kV) | Tapping range | L.V. (kV) | Vector group | Loss(kW) | No-load current (%) | Impedance voltage (%) | Weightb (kg) | ||
Load loss | No-load loss | oil | Total | |||||||
50 | 30,33,35 ,38.5 | ±5% or ±2*2.5% | 0.4 0.415 0.433 | Dyn11 Yyn0 Yd11 |
1.27 | 0.21 | 2.0 | 6.5 | 265 | 860 |
100 | 2.12 | 0.29 | 1.8 | 310 | 1150 | |||||
125 | 2.50 | 0.34 | 1.7 | 320 | 1190 | |||||
160 | 2.97 | 0.36 | 1.6 | 360 | 1230 | |||||
200 | 3.50 | 0.43 | 1.5 | 390 | 1300 | |||||
250 | 4.16 | 0.51 | 1.4 | 425 | 1480 | |||||
315 | 5.01 | 0.61 | 1.4 | 460 | 1590 | |||||
400 | 6.05 | 0.73 | 1.3 | 490 | 1760 | |||||
500 | 7.28 | 0.86 | 1.2 | 540 | 2150 | |||||
630 | 8.28 | 1.04 | 1.1 | 620 | 2380 | |||||
800 | 9.90 | 1.23 | 1.0 | 780 | 2800 | |||||
1000 | 12.15 | 1.44 | 1.0 | 850 | 3410 | |||||
1250 | 14.67 | 1.76 | 0.9 | 950 | 3890 | |||||
1600 | 17.55 | 2.12 | 0.8 | 1060 | 4620 | |||||
2000 | 19.35 | 2.72 | 0.7 | 1195 | 5345 | |||||
2500 | 20.70 | 3.20 | 0.6 | 1285 | 5960 | |||||
3150 | 24.30 | 3.80 | 0.6 | 7 | 1470 | 6695 | ||||
4000 | 28.80 | 4.52 | 0.5 | 1760 | 8350 |