• Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch
  • Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch
  • Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch
  • Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch
  • Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch
  • Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch

Kodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Recloser
Samples:
US$ 500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
ZW8-12
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CE, CCC
Phase
Three
Transport Package
Normal Export Case
Specification
830*560*817
Trademark
KODERY
Origin
China
HS Code
8537209000
Production Capacity
50pieces/Week

Product Description

Product Description

  ZW8-12 type outdoor high voltage vacuum circuit breaker is mainly used for AC 50Hz, voltage 10-12KV three-phase power system, used for breaking and closing the load current. It has overload and short circuit protection function. It can equipped with surge current time delay protector and the lightning arrester or isolating switch namely breaker and isolating switch combination etc. according to user needs.

Product Parameters
Project Parameter Project Parameter
The rated voltage 12kV Rated sequence of operation Open-0.3SOr points
-180SOr points
Rated current 630A Rated short circuit current breaking times 30time
Power frequency withstand voltage 42kV/48kV Mechanical life 10000time
Lightning shock voltage (peak) 75kV/85kV Rated operating voltage (close/split coil) DC220V AC220V
Rated short circuit breaking current (RMS) 25kA Allowable wear thickness of dynamic and static contacts 3mm
Rated short circuit closing current (peak) 50kA Isolate the fracture to disconnect the distance >200mm
 
1.Ambient temperature: upper limit +40°ºC, lower limit-30°C;
2.Altitude s 2000 meters
3.Pressure: not more than 700Pa (corresponding to the wind speed 34m/s);
4.Earthquake intensity: do not exceed 8 degrees;
5.Pollution grade: Ill class;
6.Maximum daily temperature variety less than 25ºC.
 
Detailed Photos

Kodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch

Company Profile

Kodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column SwitchKodery Zw8-12 Metered High Voltage Circuit Breaker Column Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
15
Year of Establishment
2023-01-12