  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
  • Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
EKL4B
Gross Weight Per Unit Product
0.800kg
Transport Package
Inside Box, Export Carton
Specification
1 host, 3 short circuit sensor, 1 earth sensor
Trademark
KODERY
Origin
China
HS Code
8531809090
Production Capacity
5000 Sets/Month

Product Description

Product Description

1. Short circuit fault alarm indication: Short-circuit fault sensor installed on single phase cable, monitoring the current changes of the power supply line in time, when the current change value reach or exceed short circuit current action when the alarm set point (this value can be setting according to user requirements before producing),the short circuit fault sensor emit alarm signal, the signal through optical fiber sent to the indicator host, the corresponding fault indicator light flashing, Send out alarm indicator.

2. Earth fault alarm indication: earth fault sensors installed on the bifurcation unshielded part of three-phase cable, detection of three-phase cable of zero sequence current value, when its value reach or exceed the earth current action when the alarm set point(this value can be setting according to user requirements before producing), the earth fault sensor emit alarm signal,the signal through optical fiber sent to the indicator host, the earth fault indicator light flashing, Send out alarm indicator.

3. Battery low battery alarm indication: When the indicator host internal battery voltage drops to 2.5 V, generate alarm signal,to mention maintenance personnel change the battery, the alarm signal lasts about two months. Furthermore it equipped with an external power supply interface,can use an external power source.(Type B terminal 12 "-", 9 "+"; Type A terminal 8 "+", 9 "-" AC/DC5V-10V).

4. Automatic reset: When the indicator emit alarm signals, In a set of automatic reset time, without manual reset, the indicator can be automatically reset.(Reset time: 4H.8H.12H.24H, open the host signs in the dial the code switch setting on its own)

5. Test and Reset: When the indicator emit alarm signals, press the indicator host "reset/test" button on the panel, can clear alarm status. In the normal state, hold down the indicator host "reset/test" button on the panel for 3 seconds, Panel on all the lights flashing 10 times.Type B also have relais working sound, this means the indicator is in normal working.

Product Parameters
Ambient temperature: -35ºC≤T≤+75ºC Relative humidity: ≤85%
Pollution: JP40 Automatic reset time: 4.8.12.24H (Default 12H)
Line voltage grade: ≤35KW Battery capacity: 3.6V 2Ah Service life 5 Years

Relay capacity:

AC230V/2A

Earth fault warning current:

≥20A(Default 20A)

Protection class:

IP65

Short circuit  warning current:

≥100A(Default 800A)

Accuracy: < ±10% Action delay time: 20-300ms
Short circuit withstand current: ≥20kA 2S Applicable line diameter: ≤Φ400mm
Weight of whole set: <1000g Installing hole size: 92mm×44mm
       
Detailed Photos

Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)

Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)
Company Profile

Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)Short Circuit Grounding Fault Indicator (applicable to 3kV-40.5kV distribution system)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier