Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Stainless Steel

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
12000000 RMB
Plant Area
>2000 square meters
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
  • Kodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Voltage Level
Low Voltage
Structure
Protection
Breaker Type
Fixed/Drawable
Shell Protection Grade
IP30
Application Range
High-Rise Buildings
Transport Package
Wooden
Specification
custom made size
Trademark
KODERY
Origin
China
HS Code
8538109000

Product Description





 
Product Description

GCS device is suitable for power distribution system in power plant, petroleum, chemical metallurgy textile, high-rise  building and other industries. it's three phase AC 50( 60) Hz low-voltage complete set of distribution device with rated  operating voltage of 380V( 400V) , ( 600V) and rated current of 4000A and below and is used for power distribution of power generation and power supply central control of motor and reactive power compensation in place requiring  connecting with computer and of high degree of automation, like large power plants, petrochemical system

Product Parameters

Good Quality Multifunctional Switch Complete GCS Low-Voltage Distribution Cabinet

S/N

Item

Unit

parameters

1

Rated voltage

KV

12,  24, 33,40.5KV

2

Rated current

A

630

3

Rated frequency

Hz

50

4

Rated short time withstand current

KA

20

5

Rated short circuit duration

S

4

6

Rated withstand current (peak)

KA

50

7

Rated short circuit duration of grounding switch

S

4

8

Rated short withstand current (peak) of grounding switch

KA

50

9

Rated insulation level

1min power frequency withstand voltage (effective value)

KV

(phase-phase, phase-earth)42;

(fracture) 48

Lightning impulse withstand voltage (peak)

KV

phase-phase, phase-earth)75;

(fracture) 85

10

Rated SF6 pressure (20°C gage pressure0

Mpa

0.04

11

SF6 leakage rate per year

 

1%

12

Protection degree

 

IP3*

Detailed Photos

Kodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
Kodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure

Kodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
Kodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure
Company Profile

Kodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal EnclosureKodery Kyn28-12 10kv Switchgear-Cabinet Metal Enclosure

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier